Industrial Chillers
Industrial Chillers Manufacturer for Commercial HVAC and Process Cooling
Koven Air designs and builds industrial chillers from 19-2,200 RT for factory, data center, hospital, business center, agricultural grow room and other cooling-load projects.
Industrial Chiller Systems Built Around Real Cooling Loads
An industrial chiller system should be matched to process, building profile, condenser side, maintenance access and energy target. Proper first-pass design avoids oversizing, poor part-load operation and field changes after delivery.
Unstable Load
Variable production facilities, data halls and grow rooms require capacity control, not just one nameplate number.
Wrong Heat Rejection
Water access, ambient temperatures and cooling tower limitations determine if air, water, or evaporative equipment is suitable.
Weak Part-Load Fit
Full-load COP only does so much for assessing the real energy profile of the plant. IPLV and load hours should be considered together.
Service Risk
commissioning, replacement parts, control training and warranty coverage are just as important as compressor selection.
Koven Air Industrial Chiller Range
Use these cards to move from a general industrial chillers search to a specific product page. Each path maintains homepage focus while offering engineers quick access to the correct equipment family.
Air Cooled Chiller
COP ranges of 3.23-3.35 for screw compressors and 3.25-3.28 for scroll compressors. Good fit where cooling tower water is limited.
View air cooled chillers
Water Cooled Chiller
COP 5.56-5.83 and IPLV 6.8-7.8. Strong fit for central plants with cooling tower access.
View water cooled chillers
Centrifugal Chiller
COP 6.31-6.56 and IPLV 8.5-9.5. Used in large commercial and industrial cooling plants.
View centrifugal chillers
Magnetic Bearing Chiller
AHRI-IPLV range of 10.08-11.88. Oil-free compressor path for high part-load projects.
View magnetic bearing chillers
Evaporative Chiller
COP bands from 4.27-5.08. Good choice for hot-site projects where condenser performance dictates the plant price.
View evaporative chillers
Modular Chiller
COP 3.14-3.42 and IPLV 3.60-4.30. Matches staged capacity, retrofit sites and N+1 planning.
View modular chillers
Scroll / Screw Chiller
Choices depend on load variability, the water side, and ease of access for service.
View scroll and screw chillersIndustrial Chiller Solutions Center
Comprehensive data to support your site’s specific condenser approach, capacity, and maintenance profile.
The 19-2,200 RT Chiller Selection Matrix
This matrix translates the Koven Air product line into an RFQ starter. Model number will depend on chilled water temperatures, condenser conditions, power source, refrigerant preference and site limitations.
| Cooling Load Range | Approx Capacity in kW | Recommended Chiller Type | COP / IPLV Range | Condenser Method | Refrigerant Options | Best-Fit Applications | When to Review Again |
|---|---|---|---|---|---|---|---|
| 19-234 RT | 67 kW to 823 kW | Modular chiller | COP 3.14-3.42; IPLV 3.60-4.30 | Air-cooled modular plant | R410A / R32 | Hotels, schools, staged HVAC plants, redundancy projects | Very high water-side efficiency target or large single plant |
| 30-760 RT | 106 kW to 2,673 kW | Air-cooled screw chiller | COP 3.23-3.35; IPLV 3.80-4.30 | Outdoor air heat rejection | R134A / R407C | Factories, offices, sites without cooling towers | Noise limit, high ambient site or long yearly operating hours |
| 46-1,000 RT | 162 kW to 3,517 kW | Evaporative scroll or screw chiller | COP 4.27-5.08; IPLV 5.00-6.80 | Evaporative condenser | R410A / R32 / R134A | Hot climates, factories, commercial plants with water planning | Strict water treatment limits or low-maintenance outdoor sites |
| 93-1,000 RT | 327 kW to 3,517 kW | Water-cooled screw chiller | COP 5.56-5.83; IPLV 6.8-7.8 | Cooling tower loop | R134A / R1234yf | Industrial parks, process cooling, larger commercial HVAC plants | Low load for most hours or oil-free maintenance target |
| 170-1,250 RT | 598 kW to 4,396 kW | Magnetic bearing chiller | COP 6.42-6.86; AHRI-IPLV 10.08-11.88 | Water-cooled central plant | R134A / R1234ze | Data centers, hospitals, commercial centers, uptime-sensitive plants | Poor power quality, weak controls support or near-full-load duty all year |
| 500-2,200 RT | 1,758 kW to 7,737 kW | Centrifugal chiller | COP 6.31-6.56; IPLV 8.5-9.5 | Cooling tower loop | R134A / R1234ze | Airports, subways, data centers, large industrial cooling plants | Small variable loads or sites with no cooling tower path |
Koven Load-to-Chiller Fit Map
Air-Cooled vs Water-Cooled vs Evaporative vs Magnetic Bearing Chillers
When comparing industrial chiller models, buyers need more than a brand name. The important consideration is which condenser approach, capacity band and maintenance style will suit the site.
| Decision Dimension | Air-Cooled Chiller | Water-Cooled Chiller | Evaporative Chiller | Magnetic Bearing Chiller |
|---|---|---|---|---|
| Site condition | Best where tower water, pumps or water treatment are hard to support. | Best where tower loop and plant-room support already exist. | Best where outdoor heat rejection needs better condenser performance in hot weather. | Best where the plant runs many hours at changing load. |
| Capacity band from Koven data | 30-760 RT screw; 63-160 RT scroll |
93-1,000 RT screw | 46-210 RT scroll; 70-1,000 RT screw |
170-1,250 RT |
| Part-load review | Check ambient profile and fan power. | Check tower water temperatures and pump strategy. | Check water quality and drift control. | DOE notes that magnetic-bearing chillers gain more value in plants with many part-load hours. |
| Maintenance profile | Focus on condenser coil access, airflow and controls. | Focus on water treatment, tubes, pumps and tower condition. | Focus on water quality, condenser cleanliness and outdoor access. | Oil-free bearing design can reduce oil-related service work, while controls skill still matters. |
| Procurement risk | Noise, high ambient design and roof load need early review. | Tower package, water treatment and plant-room layout need scope clarity. | Water plan and local climate data must be agreed before purchase. | Power quality, controls support and technician training need a clear plan. |
Compare COP and IPLV together
DOE FEMP purchase guidance recommends considering both full-load efficiency and IPLV. This advice is valid as most commercial chiller plants do not operate at maximum capacity full time.
Field Results in Data Centers, Hospitals, Factories and Controlled Facilities
Data Center: 2 x 1100 RT Magnetic Bearing Centrifugal Chillers
One Koven Air data center project employed two 1100 RT magnetic bearing centrifugal water-cooled chillers, model KALXCWG-1100EVT. The project record shows COP 6.83, IPLV 11.63 and modulation from 10% to 100%.
Factory Verification and
Traceability Before Shipment
For international orders, product specifications are not sufficient. Koven Air provide buyers with an audit of the manufacturing process before a industrial chiller is shipped from the factory.
Processes
Standard production steps support repeatable manufacturing.
Machining Steps
Sheet-metal precision work is tracked before assembly.
Trace Points
Manufacturing process traceability follows each order.
Inspections
Factory inspection checks are completed before shipment.
Design & Parameter Review
The Koven Air team verifies load data, water temperatures, condenser conditions, power requirements, and site conditions prior to confirming the final model selection.
Modular Assembly Line
The facility’s automated assembly line uses intelligent robots for accurate sheet metal work, piping and component fitting.
Laboratory Testing
A professional chiller and heat pump laboratory performs equipment tests before equipment release.
24-Hour Aging Test
All units can undergo aging tests before shipping; testing results are saved in the order record.
Procurement Support From Load Verification to Lifetime Technical Guidance
A industrial chiller order affects multiple departments – engineering, purchasing, installation and service. Koven Air’s specialized teams focus on pre-sales, production and post-sales support, preparing each team with the information they need.
RFQ inputs that speed up model selection
Send cooling capacity, chilled-water supply and return temperatures, evaporator flow, condenser conditions, 50 Hz or 60 Hz power supply, refrigerant preference, application type and installation limits to Koven Air.
Request a QuotePre-Sales
The engineering team reviews all cooling load data, water temperatures, ambient conditions, and potential risks before confirming the equipment selection.
In-Sales
After manufacturing and testing, Koven Air provides technical assistance for on-site installation, debugging, and on-site modifications.
After-Sales
Koven Air provides lifelong technical support service for free. If any issue occurs within the warranty period, the company will handle it promptly and conducts regular training for its customers, contractors, and engineers.
Chiller System Choices Are Moving Toward Part-Load and Refrigerant Review
Selecting modern chillers has become more than just determining the cooling capacity. Customers also consider factors such as the number of hours the plant will operate at part load, the ease of service access, the preferred refrigerant path, and the overall long-term plant costs.
IPLV belongs beside COP
AHRI lists ANSI/AHRI 550/590 and ANSI/AHRI 551/591 for rating water-chilling packages and heat pump water-heating packages using the vapor-compression cycle. Ask for both full-load and part-load data during evaluation.
Low-GWP planning affects specs
EPA describes the AIM Act HFC phasedown and sector restrictions that apply to refrigerants used in air conditioning and heating equipment. Review refrigerant choices, such as R1234ze and R1234yf, early in the design process.
Maintenance is part of TCO
DOE suggests that the elimination of oil in magnetic-bearing designs can reduce the maintenance costs associated with oil-related service issues. However, this is dependent on factors such as controls setup and load profile.
Standards belong in the RFQ
Use ANSI/AHRI 550/590 for I-P rating language and ANSI/AHRI 551/591 for SI rating language when a project asks for rated chiller data. Keep ISO, local electrical code and witness-test forms separate from capacity claims.
Industrial Chiller Engineering & Evaluation Tools
Chiller Selection Finder
Use this first-pass finder before an RFQ. It narrows the likely industrial chiller family, then your engineer can check the actual cooling load and site limits.
Open ToolChiller Efficiency Comparison Tool
Compare Koven Air chiller families with the same lens buyers use during early engineering review. COP shows full-load efficiency, while IPLV helps screen part-load behavior.
Open ToolData Center Chiller Energy Check
This estimator helps a data center team frame the energy review before asking for a magnetic bearing chiller selection. It uses a project-specific 35 percent reference from supplied Koven Air case material, not a guaranteed result.
Open ToolChiller Buyer FAQ
How much does an industrial chiller cost?
The purchase price is affected by several factors, including capacity, type of compressor, condenser type, refrigerant, control features, the extent of testing required, shipping logistics, and the location of the project. Comparing a 100 RT modular chiller with a 1,100 RT magnetic bearing centrifugal chiller, you’ll find the purchasing processes differ greatly. Start by submitting the load profile, desired chilled-water temperatures, condenser limitations, power supply, and site plans to receive comparable quotes. Compare purchase prices, energy consumption, maintenance access, and the risk of a shutdown.
Which is better, air-cooled or water-cooled chillers?
Air-cooled chillers are ideal for installations without access to tower water. If you already plan to install and maintain a tower, water pumps, and water treatment systems, water-cooled chillers can offer significant energy savings.
How do I choose between screw, scroll, centrifugal and magnetic bearing chillers?
Scroll chillers are suitable for smaller cooling loads and modular staged plants. Screw chillers are widely used in industrial and commercial chiller system applications in both medium and high-capacity ranges. Centrifugal and magnetic bearing chillers are best suited for large central plants, with magnetic bearing chillers being particularly effective in situations where part-load efficiency and oil-free compressor operation are essential.
What chiller type is best for a data center?
Data center owners prioritize reliable operation, consistent chilled-water supply, precise control at part load, and ease of maintenance. Koven Air has provided a two-unit installation of 1100 RT water-cooled magnetic bearing centrifugal chillers to a data center facility. The selection should be based on redundancy requirements, condenser water conditions, controls, power quality, and a clear local service plan that aligns with the PUE target of the facility.
What is the difference between a commercial chiller and an industrial chiller?
A commercial chiller often serves comfort cooling, whereas an industrial chiller may be used for production process, data room cooling, cold storage, or controlled agriculture.
Do magnetic bearing chillers use oil?
Magnetic bearing chillers suspend the compressor shaft using magnetic force, eliminating the oil system found in many traditional compressors. This feature, along with the reduction in oil-related maintenance, is highlighted by DOE as a benefit of magnetic bearing technology. However, to ensure proper functioning, the facility still needs a skilled controls technician, consistent water quality, stable power, and appropriate commissioning. An oil-free compressor cannot compensate for an inadequate plant design.
What information is needed for chiller sizing?
When selecting a chiller, you should begin by providing the required cooling capacity, the desired inlet and outlet water temperatures, ambient design conditions, the process fluid being cooled, the available power supply, site elevation, and the permissible equipment footprint. Next, provide the annual load profile, the desired redundancy level, refrigerant preferences, and any local service restrictions. Koven Air can assist in reviewing this information before making a model selection.
Does Koven Air provide installation and commissioning support?
Yes. Koven Air can send qualified technicians to the site to provide installation guidance and troubleshooting assistance. Any issues encountered within the warranty period are promptly addressed.